Hematopoietic Stem Cell/Bone Marrow Recipient - Provincial
Discipline
Histocompatibility and Immunogenetics (HLA)
Overview
Description
- If WBC count is less than 1 x 10^9/L, please contact HLA laboratory 306-655-5205 before drawing specimen
Alias
- HLA testing
Specimen Information
Specimen types accepted
- Whole blood
Specimen collection container
- Preferred collection container: Lavender top (EDTA) or Yellow top (ACD-A) 8.5 mL
- Alternative collection container: None
Required volume
- Optimal volume: 2- 4 mL Lavender top or one - 8.5 mL Yellow top (ACD-A)
- Minimum volume: as per optimal volume
(Submitting the minimum volume makes it impossible to repeat the test or perform confirmatory/reflex testing. In some situations, a minimum volume may require a second collection.)
Transport and stability
- Tubes must be shipped at room temperature (20-25°C) and arrive in laboratory within 7 days
- Do not expose to cold or extreme heat
Rejection criteria
- Unlabeled, illegibly-labelled, mislabeled, or inadequately labelled specimens
- Original labeling must be present and visible
- Incomplete, inaccurate, or illegible information on the requisition
- Discrepancies between requisition patient information and specimen label information
- Collected by – required for all collections
- Date and time of collection
- Pathology and Laboratory Medicine Acceptance and Rejection Criteria
Testing Information
Relevant clinical history
- White Blood Cell count
- Recent transfusions
- Diagnosis
- Ethnicity
Performance
Methodology
- High resolution molecular typing (NGS)
Days/times performed
Availability |
|
Testing site |
|
Maximum laboratory time
- 21 days from receipt of specimen
Specimen retention time
- Specimen (extracted DNA) 5 years
Other information
- Forms required - HLA Test Request Form
Last Updated: July 4, 2024