Manganese, Blood (Referred Out) - Saskatoon
Discipline
Biochemistry
Overview
Description
Ordering Recommendations
- High concentrations of gadolinium and iodine are known to interfere with most trace element tests. If gadolinium- or iodine-containing contrast media have been administered, a specimen should not be collected for 48 hours
Test ordering requirements
Preferred Specimen Collection
- Refer patient to a LifeLabs Laboratory Health Services Centre or a Hospital Test Centre able to process specimens within required time frame
Specimen Information
Specimen types accepted
- Plasma
Specimen collection container
- Preferred collection container: Royal Blue (K2EDTA)
Collection procedure
- Centrifuge and separate plasma from red blood cells within 24 hours collection
- Aliquot plasma into a polypropylene tube
Required volume
- Optimal volume: 6.0mL
- Minimum volume: 2mL
(Submitting the minimum volume makes it impossible to repeat the test or perform confirmatory/reflex testing. In some situations, a minimum volume may require a second collection.)
Transport and stability
- Store and ship refrigerated.
Rejection criteria
- Specimens received where the proper collection protocols were not followed
- Pathology and Laboratory Medicine Acceptance and Rejection Criteria
Performance
Days/times performed
Availability |
|
Testing site |
|
Maximum laboratory time
Results Reporting
- 7 day turnaround time by testing laboratory